1.0
OBJECTIVE:
To lay down
the procedure for Sampling and Testing for Rinse water and swab samples after
cleaning.
2.0
SCOPE:
This SOP is
applicable to cleaning of all equipment/accessories used in Production during
Product to Product Changeover at -------------------------
3.0
RESPONSIBILITY:
3.1 Concerned department and Production personnel
responsibility for the intimation to IPQA/QA personnel for Rinse/Swab sampling
after cleaning.
3.2 IPQA responsibility for the Complies of the SOP.
3.3 Quality Control Officer/IPQA responsible for the
sampling.
4.0
ACCONTABILITY:
The
Accountability for implementation and compliance of the SOP is of Quality
Assurance Head.
5.0
PROCEDURE:
5.1 To ensure that the procedure adopted for cleaning
shall be effective and able to remove traces of active ingredient of the
previous product which may cause cross-contamination from manufacturing
equipment to the product. To provide procedure for analysis of Rinse water and
swab samples after cleaning of equipments.
5.2 Precaution for Sampling of Rinse /Swab water for
analysis:
5.2.1
Before taking Rinse / Swab sample, sample bottle/ test tubes should be
clean and dry.
5.2.2
Before taking Rinse / Swab sample, equipment shall be visually cleaned
and free from odour.
5.2.3
After taking Rinse / Swab sample, IPQA officer shall be checked sample
for particulate matter and odour, sample comply for particulate matter and
odour, then sample send to QC for further analysis, if particulate matter or
odour is present in sample inform to production officer to re-clean the
equipment and again take the sample.
5.3 The production officer shall intimate to the QA
officer for sampling of Rinse water / swab as per the Swab/Rinse Analysis
Request format which is a part of
respective Product Batch Record.
5.4 For Loan License Products where the Batch Records are
given by the party, the Swab/Rinse request shall be given as per format No.
F/QA-010-01.
5.5 After receiving the request, QA officer with labeled
bottles, test tubes and swabs will proceed for the collection of samples. The
samples should be collected as per the format No.: F/QA/010-02.
5.6 Procedure for Sampling of Rinse water for analysis:
5.6.1
Clean the
equipment as per the respective SOP. Ensure visually clean that the equipment
is free from any residue. Collect about 100 ml of sample, for each active
ingredient to be estimated in labeled amber coloured bottle, from the final
washing collection of the contact part of the equipments / Container/
Accessory.
5.6.2
If Rinse
sample is not collected from final washing than collect the sample as
below Procedure.
5.6.2.1
Rinse the
equipments through sprayed rinse solution from top to bottom and collect the
sample.
5.6.2.2
Rinse
solution quantity depends upon the capacity of equipments.
Taking rinse solution as per below
mention qty.
100 ltr to 250 ltr rinse solution Approx
1 ltr
251 ltr to 500 ltr rinse solution
Approx 2 ltr
501 ltr to 1000 ltr rinse solution
Approx 3 ltr
More than 1000 ltr rinse solution
Approx 5 ltr.
5.7 Procedure
for Sampling of swab for analysis:
5.7.1
Swab sampling
shall be carried out using cotton swab. Swab samples shall be taken from
equipment/ container surface as per the photograph.
5.7.2
All swabs
will be pre-wetted with solvent properly. The surface area to be swabbed is
100Cm2 (10cm x 10cm) Swabbing is done in painting motion across the
surface, first applying the swab in a vertical motion, and then applying the
swab (after rotating it 90°) in an horizontal motion than dip the swab cotton in 10ml purified
water.
5.7.3
If area is
not sufficient for swab, take tentative area for example Die and punch, RMG Impeller & Chopper blades, multimill inside Housing, small spares and
screens
Octagonal blender butterfly valve and baffle and Coater Spray gun
assembly, Baffle, Discharge Chute, Impeller of holding tank, Stirrer of
homogenizer etc.
Horizontal
5.8 Rinse water
/ Swab sample analysis:
5.8.1
The samples
shall be immediately transferred to quality control department, along with Rinse water / swab analysis request cum
report.
5.8.2
After the
receipt of the Rinse water / swab analysis request and the sample, the quality
control department shall allot a unique QC Reference number to the Rinse water
/ swab analysis request cum report.
5.9 It shall be brought to the Quality Control Department where
an A. R. No. is allotted as follows PQC/ST/XYYY, PQC/RT/XYYY
Where
PQC-Stands for Preet Quality control-
ST-Stands for Swab test
RT- Stands for Rinse water
X-Stands for the current year like 8
for 2018 year
YYY-Stands for serial number of the
test performed in a particular year
5.10 If only
visually checking for clarity and any presence of particulate matter in the
solution is required, (e.g. in case of Batch to Batch Changeover – Type “A”
cleaning) than such samples shall be checked by IPQC personnel, while the
samples requiring the chemical analysis shall be analyzed by the QC Department.
If the same product is in the process then after 72 hrs (irrespective of how
many batches manufactured) the complete change over will be done (Type “B”
cleaning). But there is no need for sending the swab/rinse water sample to QC.
5.11For the samples
requiring the visual cleanliness check, following steps shall be followed:
5.12The sample
from the bottles shall be first transferred in the 250 ml capacity clear glass
beaker, along with the same amount of the purified water in another 250 ml
capacity clear glass beaker.
5.13
Samples shall
be checked visually respectively from top and side of the beaker. The sample
which requires chemical analysis shall be analyzed by QC as per the respective
SOP. After the clearance of the samples by QC / IPQC reports shall be compiled
and sent to IPQA for final review. The IPQA shall issue the approved report to
the Production department.
5.14
If the Rinse
water / analysis does not meet the acceptance criteria, then the investigation
shall be carried out as per the SOP
for Deviation Handling and the corrective and preventive actions shall be
mentioned. The equipment shall be cleaned again and sample sent to QC for
reanalysis.
5.14.1
Tacking swab/
Rinse location as per the below photograph.
QA officer
check all the dead spots area / hard to clean area visually as per Photographs
for cleanliness before taking swab or Rinse.
5.14.2
QA Officer shall be take rinse from final washing through discharge chute if rinse is not
collect then take swab from RMG Impeller
& Chopper blades and inside
of Discharge chute are cleaned as
per as per Photograph.
5.14.3 QA Officer shall be take
rinse from final washing through
discharge chute if rinse is not collect then take swab from inner surface ,
Discharge chute from inside of
Mechanical sifter and sieves edges as per as per Photograph.
5.14.4 QA Officer shall be take
swab from multimill
Discharge chute from inside Housing, small spares and screens as per Photograph.
5.14.5 QA Officer shall be take
rinse from final washing through drain
point if rinse is not collect then take swab from FBD lower
plenum, view window, dutch mesh corner as per Photograph.
5.14.6 QA Officer shall be take
rinse from final washing through
butterfly valve if rinse is not collect then take swab from octagonal blender
rubber gasket, butterfly valve and baffle as per Photograph
5.14.7 QA Officer shall betake
swab from Upper and lower turret and five die hole as per Photograph.
5.14.8 QA Officer shall betake
swab from Punch tip, Die And Discharge Chute as per Photograph
5.14.9 QA Officer shall betake
swab from De-duster screen and Discharge chute as per Photograph
5.14.10QA Officer shall be take
swab Spray gun assembly, Baffle, Discharge Chute, Discharge Chute
Cover, Outlet of holding tank, Impeller of holding tank Inlet & outlet of
colloidal mill , Stirrer of homogenizer
as per Photograph
5.14.11Acceptance Criteria :
The acceptance criteria for the clearance of the Rinse water/ swab
samples shall be as follows
Type of analysis |
Acceptance criteria |
UV
Spectrophotometer (Absorbance
between 200 to 800 nm ) |
Not more
than 0.05 ABS |
Visual
Checking |
Sample
should be free from foreign particles and odorless. |
5.14.12Frequency: Product change over
6.0 LIST OF ANNEXURE AND FORMATS:
Sr. No. |
Title of Format |
Format No. |
01 |
Swab / Rinse water analysis request/report |
F/QA-010-01 |
02 |
Swab / Rinse Sample Point |
F/QA-010-02 |
7.0 REFERENCE:
7.1 SOP-QA-001
7.2 F/QA-001-01
8.0 REVISION HISTORY:
Sr. No. |
Date |
Reason for Revision |
Revision No |
1.
|
31/10/2018 |
New SOP |
R0 |
2.
|
31/10/2020 |
Schedule Revision |
R1 |
9.0
ABBREVIATIONS:
Sr. No |
Abbreviations |
Details |
01 |
SOP |
Standard operating procedure |
02 |
UV |
Ultraviolet |
03 |
IPQC |
In-process Quality Control |
04 |
QC |
Quality Control |
05 |
ABS |
Absorbance |
06 |
Ltr |
Litre |
07 |
Ml |
Milli liter |
08 |
Nm |
nanometer |
END OF DOCUMENT
SWAB
/ RINSE ANALYSIS REQUEST / REPORT
From: Production Department. Date:
To: Quality Assurance
Product Name: Batch No.:
Please
collect the Swab / Rinse sample for residual analysis as applicable.
Sr. No. |
Date |
Time |
Equipment Name |
Equipment I.D. No. |
Previous Product
Name |
Previous Batch No. |
A.R. No. |
Result |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Analysis results attached